• info@geesysindia.com
  • +91 99620 12354
  • Gallery
  • Downloads

Quick View

DCDB Ranges
  • String Shield
  • MI Guard
  • String Guard
  • Combo Guard
String Shield
  • ED5 Series
  • ED10 Series
ED5 Series
  • ED50 Series
  • ED51 Series
  • ED52 Series
  • ED53 Series
  • ED54 Series
ED10 Series
  • ED100 Series
  • ED101 Series
  • ED102 Series
  • ED103 Series
  • ED104 Series
MI Guard
  • MD5 Series
  • MD10 Series
MD5 Series
  • MD50 Series
  • MD51 Series
  • MD52 Series
  • MD53 Series
  • MD54 Series
MD10 Series
  • MD100 Series
  • MD101 Series
  • MD102 Series
  • MD103 Series
  • MD104 Series
String Guard
  • GD5 Series
  • GD10 Series
GD5 Series
  • GD50 Series
  • GD51 Series
  • GD52 Series
  • GD53 Series
  • GD54 Series
GD10 Series
  • GD100 Series
  • GD101 Series
  • GD102 Series
  • GD103 Series
  • GD104 Series
Combo Guard
  • EC Series
  • GC Series
  • MC Series
EC Series
  • EC50 Series
  • EC10 Series
  • EC52 Series
  • EC12 Series
  • EC54 Series
  • EC14 Series
GC Series
  • GC50 Series
  • GC12 Series
  • GC52 Series
  • GC14 Series
  • GC54 Series
MC Series
  • MC50 Series
  • MC12 Series
  • MC52 Series
  • MC14 Series
  • MC54 Series
GEESYS - Expert in General Electrical and Electronics
  • Company
    • GEESYS

      • About us
      • Integrity
      • Milestones
      • Brand Identity
      • Awards | Certifications
      • Sustainability
      • Inclusion | Diversity
      • Data Privacy | Cookies policy
      • Corporate Policies
      • News | Insights

      R&D

      • R&D Policy and Organization
      • R&D Activities
      • Intellectual Property Strategy

      ESG

      • Corporate Governance
      • Ethics | Compliance
      • Environment
      • Human Rights | People Development
      • Customer
      • Supply chain
      • Community Engagement
      • Risk Management

      Customer Success Stories

      Selling to GEESYS

      Working at GEESYS

      Clients

      Contact us

      Forum

  • Products
    • Power Generation

      • Solar DCDB
      • Solar Combiner Boxes
      • Solar ACDB
      • Solar AC Combiner Boxes
      • Solar AC|DC DB
      • Solar Reverse Panel
      • Solar Junction Boxes
      • Solar Dc String Combiner Boxes
      • String Monitoring Box
      • Weather Monitoring System
      • Solar Pump Control Panel
      • Solar Metering Panel
      • Solar Charge Controller
      • Solar Converters
      • Solar PCU
      • Solar Panel Structures
      • Solar Array Junction Boxes

      Power Conditioning

      • Servo Voltage Stabilizers
      • Isolation Transformers
      • LT Distribution Panels
      • Bus Ducts
      • AMF panel
      • APFC Panel
      • Automation Panels
      • Motor/Pump Starter Panel
      • HT VCB Panel
      • Control Transformers
      • Inverter Transformers
      • Fire Fighting Panels
      • Rising Main
      • Construction DB
      • Metering Cubicle

      Power Backup

      • Power Inverter
      • Online UPS
      • EV Charger
      • Lift Inverters
      • Frequency Converters
      • Static Transfer Switches
      • Industrial Battery Chargers

      Security | Automation

      • Access Control System
      • Fire Alarm System
      • Water leakage Detection
      • Video Surveillance System
      • Public Addressing System
      • Burgular Alarm System
      • Rodent Repellent System
      • Home Automation system

      Earthing Products

      • Earthing Electrodes
      • Earthing Pipes
      • Lightning Arrestors
      • Earthing Minerals
      • Earthing Accessories

      Residential

      • Voltage Stabilizers
      • Automatic Phase Changers
      • Home UPS
      • EB Metering Panels
      • Water Level Controller
      • Distribution Boards
      • Solar BOS Kit
  • Solutions
      • TeleCom
      • Banking
      • SOHO
      • Manufacturing
      • Health Care
      • Lifts
      • ATM
      • Government
      • Building
      • Petrol Bunks
      • Institutions
      • Machine Tools
      • Datacentres & IT
      • Hotels
      • Business
      • Energy & Infrastructure
  • Services
    • Your Needs

      • Rapid Response
      • Lifecycle Management
      • Performance Improvement
      • Operational Excellence

      Service Offerings

      • Advanced Services
      • End of Life Services
      • Engineering | Consulting
      • Extension | Upgrades | Retrofits
      • Installation | Commissioning
      • Preventive Maintenance
      • Replacement
      • Service Agreement
      • Spares | Consumables
      • Trouble Shooting | Repairs
      • Value Added Services

      Support

      • Contact Technical Support
      • How to Buy
      • Terms and Conditions
      • Tools
      • Training & Education
      • Warranty Terms | Returns
      • Product Registration
  • Shop
  • Contact us
  • Home
  • Products
  • Power Generation
  • solar-acdb
  • Solar ACDB

Solar-ACDB-Single-Phase-with-Tb-Mcb-Spd

  • Solar ACDB
  • Solar ACDB 1-5kw
  • Solar ACDB 5-15kw
  • Solar ACDB 30-40kw

solar-acdb-single-phase-with-tb-mcb-spd

The ACDB box is made of epoxy powder coated metal casting. Three feeders are provided in ACDB with MCB of Required capacity installed at each feeder in the ACDB. One Electronic Energy Meter, ISI make, is provided in ACDB to measure the consumption of power from SPV Power Plant.
A separate dedicated feeder from conventional line to PCU as well as ACDB is also provided. A separate change over switch of required capacity is provided in the ACDB to isolate the existing connected load from the solar system & switch it over to the existing convention power (Mains), in case of emergency.Solar ACDistribution Boxes are installed immediately after the solar PV Grid-tie inverter. Solar ACDB - is an important part of SPV system. It gives extra protection to the system in case of failures on load side.
ACDB is made up of breaker, isolators etc. To ensure maximum protection to the sophisticated electronic equipment, It has provision for surge protection in the box along with fuses.
Solar DCDB - is used to protect the system if there is any fault during failure on DC side. A very crucial part of SPV system as there should be adequate protection on DC side. The DCDB incorporates isolator/Breaker to switch off the system during fault. It also have surge protection to save your system from any surges occurred due to fault or other phenomenon. SOLAR ACDB DCDB is a part of solar power plant.
When sunlight is incident on the solar panel, the current and voltage is generated in the terminals of solar cell. A grid connected solar Photo Voltaic system consists of the following components.Solar Photo Voltaic array, Array combining box, DC Cabling, DCDB, Inverter, AC Cabling and ACDB. In Other words, Solar ACDB is AC Distribution board and Solar DCDB is DC Distribution Boards A separate change over switch of required capacity is provided in the ACDB to isolate the existing connected load from the solar system & switch it over to the existing convention power (Mains), in case of emergency.Solar ACDistribution Boxes are installed immediately after the solar PV Grid-tie inverter.

Series: String Shield
Dispatches: Between 10-15 Days
Price: INR 25000/-* Onwards
  • Introduction
  • Features
  • Technical Specifications
  • Applications
  • Documents
  • FAQs

Introduction

Solar ACDB

The main purpose of the ACDB is to eliminate the operation of the load at the immediate PCU O/P end and also provide flexible operation of different loads like Street lights, general home or office lights and optional loads that optionally operated (On/Off).

GEESYS PV AC/DC distribution box consists of DC distribution unit and AC distribution unit. The DC distribution unit is mainly used to collect the DC from the PV panels and supply it to the inverter. The AC distribution unit is used to provide the AC converted by the inverter for the grid connection interface. GEESYS DBW1.5~20K AC/DC Distribution Box is mainly used in small and medium PV systems and it may provide a complete PV system solution for the customers together with our small and medium power inverters. GEESYS offer several purpose built ACDBs like ACDB for tied inverter, ACDB for off grid inverter.

Features

  • IP 65/66 protected(PC Enclosure)
  • Short circuit & overload Protected
  • Over voltage protected(P+N)
  • No Air condensation
  • Cu wired with FR insulation & UV resistant
  • Tested wire harnessing to ensure high conductivity
  • No Earth Leakage Current
  • Suitable for TT & TN System
  • Easy to Install & Service
  • World class quality with best industry price
  • Designed for 25 years life time

Technical Specifications

Model GPRO-GD5X GPRO-GD10X
Maximum Voltage in open Circuit 500V 1000V

Input

No of DC inputs 1-6 1-12
Maximum Input Fuse* Rating, A * 6/10/12/15/20/30
Max Input Current in short Circuit
Max. input current in short circuit at STC
Maximum string current per fuse holder with all string fuse* Reduction factor 0.55
Conductor Size , Sq.mm 4 — 10 Sq.mm

Output

No of DC inputs 150 Sq.
Maximum DC Current, A * Upto 32A Upto 32A
Conductor Size, Sq.mm 4 — 10 Sq.mm 4 — 10 Sq.mm
Cable gland clamping range,mm 12-32 -

Protection

DC inputs overcurrent protection Protection on both polarities, gPV fuses, size 10 x 38 mm, max. rating 30 A (fuses not provided with product)
Surge Protection Device (SPD)* <=600V DC, Class C/Class B/ Class B+C 1000V DC, Class C/Class B/ Class B+C
Electric shock protection Class II equipment

General

Ingress Protection IP66/65
Enclosure Type PS*/PC,
Transparent Top Cover
Wall mounting Yes
Bus Bar* Yes
Operating conditions Temp: -20 to +55 Deg. C , RH : 0 — 95% non cond
Type of Protections Short-Circuit,Surge
International standards followed IEC 60364
Design Life 25 years +

Applications

  • Solar PV Power Plants

Documents

Catalogue Format Size Date
 Solar ACDB GAx1NR PDF 2.1MB 21Jun2019
Catalogue Format Size Date
 Solar ACDB 5 TO 33 KWP PDF 2.1MB 21Jun2019
User Guide
 Warranty Terms & Conditions  PDF  326.2kB  21Jun2019
Certification      
 Solar ACDB Test Report  PDF  1.2 MB  21Jun2019